• Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
  • Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
  • Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
  • Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
  • Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
  • Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater

Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater

After-sales Service: 24 Hours Online
Warranty: One Year
Application: School, Hospital, Lab
Customized: Customized
Certification: CE
Structure: Portable
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Henan, China
to see all verified strength labels (12)

Basic Info.

Model NO.
SH-II-4C
Type
Hot Plate
Name of Commodity
Magnetic Stirring Hot Plate
Model
Sh-II-4c
Max. Volume
5000ml
Heating Plate Size
190X190mm
Heating Plate
Ceramic Coated
Speed Adjust Range
200-2000r/Min Digital Display
Motor Power
20W
Heating Power
600W
Accuracy of Temp Control
+-1 Degree C
Temperature Range
Rt-380 Degree C
Max Temp.
380 Degree C
Sensor
PT100
Overall Dimensions
320X190X125mm
Packing Dimensions
390X240X230mm
Weight
6000g
Transport Package
Plywood Box
Specification
550x380x200mm
Trademark
WollenLab
Origin
China
HS Code
8479820090
Production Capacity
1000sets/Month

Product Description

Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater

Features:

1. Stretched shell and cover prevent leaking.
2. Heating and stirring can proceed simultaneously.

Ceramic
 Magnetic Stirring Hot Plate with the following functions:


SH-4C

 
1. Setting temperature precisely, stepless adjustable stirring speed .
2. Large LCD display, temperature and rotate speed can be displayed simultaneously.
3. Double sensors: outer PT100 temperature sensor to control liquid temperature precisely, inner K model sensor to control hot plate temperature.
 
SH-II-4C
 
1. Setting temperature and stirring speed precisely,. With speed switch to start or stop stirring at any time.
2. With timing function (0~9999mins), the time can be set according to customer's requirements, with sound and light alarm function.
3. Double sensors: outer PT100 temperature sensor to control liquid temperature precisely, inner K model sensor to control hot plate temperature.
4. One key to shift inside and outside sensor easily and precisely.
5. Large screen LCD display can indicate temperature, rotational speed and timing at the same time.
Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
Technical Parameters:
 
Model SH-4A SH-4B SH-4 SH-4C SH-II-4C
Mode Heating Stirring Heating+ Stirring Digital+Heating+Stirring


Function
Max. Volume 5000ml
Stirring Speed No 200~2000rpm
Working Time Continuous
Mini Stirring Speed No 200rpm
Max Temp. 380ºC No 380ºC



Structure
Exterior Iron plate welding, surface spraying
Heating Plate Ceramic Coated
Driving Mode No Motor
Motor Power No 20W
Heating Power 600W No 600W
Stirrer No PTFE
Controller Continuous
Operation
Yes
Setting Mode Scale Digital
Speed Display
Mode
Scale Digital Digital
Timer No Yes
Operation Function No Yes
Sensor No PT100 PT100
Specification Exterior Size 320x190x125mm
Packing Size 390x240x230mm
Plate Size 190x190mm
Plate Load 10kg
Power Supply 110V or 220V 50/60Hz
NW/GW 5/6kg
Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
Precautions:
 
1. Do not use dry boil.
2. Please do not connect the ground wire to ensure safe use.
3. In order to extend the using of the product, all magnetic stirring motors are equipped with fan of heat dissipation function, so when you doing heating experiments, especially high temperature heating tests, the instrument cannot be used for heating alone. Be sure to adjust the motor to rotating or middle Speed rotation state (or idling) to prevent the motor and electrical appliances from being damaged by high temperature radiation. If the motor cannot start to rotate, contact for maintenance in time.
4. When the high-temperature heating is finished, please turn off the heating first, wait a few minutes for the residual temperature to dissipate, and then turn off the stirring.
5. The heating part has a high temperature, so be careful when working to avoid burns.
6. If there are wet hands, liquid spills, or long-term exposure to excessive humidity, the leakage phenomenon should be dried in time or dried naturally before use to avoid danger.
7. When it don't use for a long time, please store it in a dry place without corrosive gas.
8. When the ambient humidity is relatively high, induction electricity may be transmitted to the shell through the insulation layer. Please connect the ground wire to avoid leakage and pay attention to ventilation.
9. Relative humidity: 35%-85% (no condensation).
Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater

Our Services:

Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater
Laboratory Digital Temperature Control Hot Plate Magnetic Stirrer Heater

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now